Urusara 7 offers a unique, total comfort
experience for any lifestyle. Powerful year-round cooling and dehumidifying is
just the beginning. Urusara 7 puts the latest advances in Japanese
air-conditioning technology at your fingertips. Features like the new
circulation airflow wrap you in a cloud of effortless comfort while advanced
streamer technology effectively purifies air. This design excellence extends to
the sleek, award-winning indoor unit.
FEATURE
Urusara 7 puts the latest Japanese air
conditioning technology at your fingertips, offering a unique, total comfort
experience for any lifestyle. Powerful year-round cooling and dehumidifying are
just the beginning. Urusara 7 is also the world’s first air conditioner to use
next-generation R-32 refrigerant1. Along with its many energy-saving features,
this higher performance refrigerant gives Urusara 7 unrivalled energy
efficiency2.
SPECIFICATION
FUNCTION
- Comfort Sleep Timer
This function controls the indoor temperature
using a V-shaped pattern based on sleep science, helping to promote restful
sleep. It is only necessary to set a wakeup time.
- Wireless Remote Control
The large LCD and backlit buttons allow easy
operation in the dark. Frequently used functions are conveniently located on
the front of the controller.
- Breeze Airflow
This function recreates the natural rhythm of a
gentle breeze. With this airflow pattern, even people who are sensitive to drafts
feel comfortable when air is directed towards them.
- 3-Area Intelligent Eye (Focus)
Intelligent Eye has infrared sensors which detect
human movement in left, right and centre zones. Intelligent Eye Focus
automatically adjusts horizontal airflow to send air directly to a person.
- Vertical Auto-Swing
This function automatically moves the flaps up
and down to distribute air across a room.
- Countdown Off Timer
The operation stop time can be preset for a
period of 0.5 to 9.5 hours in 30 minute increments.
- Information Display
The LCD provides various details on current
operation, including temperature and humidity. It also displays information
such as total energy use over several days.
- Inverter Powerful Operation
This function is convenient for boosting
cooling-heating performance for a 20 minute period both when the air
conditioner is first turned on or it is necessary to change the room
temperature quickly.
- Horizontal Auto-Swing
Horizontal Auto-Swing automatically moves the
louvers to the left and right to cover a room with cool-warm air.
- Wide-Angle Louvers
The smoothly curved Wide-Angle Louvers provide
wide airflow coverage for effective operation no matter where the indoor unit
is placed in a room.
- Indoor Unit On-Off Switch
The unit can be conveniently started manually in
the event the wireless remote controller is misplaced or the wireless remote
controller batteries are not charged.
- Wipe-Clean Flat Panel
The flat panel design can be cleaned with only the
single pass of a cloth across its smooth surface. The flat panel can also be
easily removed for more thorough cleaning.
- Anticorrosion Treatment of Outdoor Heat Exchanger Fins
The outdoor unit’s heat exchanger fins are
processed using a special anticorrosion treatment.
- Quick Heating Timer
Heating operation can be preset to turn on one
minute after the set wakeup time. Warm airflow starts just one minute later.
- Child-Proof Lock
This function allows users to lock operation
using the wireless remote controller. It is useful for preventing setting
changes if children play with the controller.
- 24-Hour On-Off Timer
This timer can start or stop the air conditioner
within a 24-hour period. It can be preset in 10-minute steps by pressing the
On/Off timer button on the wireless remote controller.
- Econo Mode
This mode limits maximum running current and
power consumption. This improves operating efficiency and also prevents circuit
breakers from being overloaded.
- 3-Area Intelligent Eye (Comfort)
Intelligent Eye has infrared sensors which detect
human movement in left, right and centre zones. Intelligent Eye Comfort
automatically adjusts horizontal airflow to avoid blowing air onto a person.
- Auto Off Operation
Auto Off Operation uses 3-Area Intelligent Eye to
automatically stop operation if no movement is detected in a room. A detection
period of one or three hours can be set.
- Auto Fan Speed
The microprocessor automatically controls fan
speed to adjust the room temperature to the set temperature.
- Sarara Dry Operation
This dehumidifying function stabilises the room
temperature and prevents overcooling, even for people who are particularly
sensitive to cold.
- 3-D Airflow
This function combines Vertical and Horizontal
Auto-Swing to circulate a cloud of cool/warm air right to the corners of even
large spaces. The flaps and louvers swing in turn.
- Photocatalytic Air-Purifying
While the filter’s micron-level fibres are able to
effectively trap dust, its photocatalyst has the ability to adsorb odours.
- Dry Cooling Operation
This combined dehumidifying and cooling operation
dehumidifies by cooling at a low airflow rate, resulting in a lower room
temperature.
- Mould-Proof Operation
The streamer discharge dries the inside of the
indoor unit, heat exchanger and airflow routes. It effectively prevents the
growth of both mould and odour-causing bacteria.
- Installation Position Setting
The room shape and installation position can be
set on the wireless remote controller. This enables optimal control of the
horizontal airflow direction.
- Streamer Discharge Air Purifying
The streamer discharge decomposes bacteria and
mould adsorbed by the indoor unit’s photocatalytic filter.
- Circulation Airflow
This function uses the Coanda effect to rapidly
achieve the set temperature. The double air intakes and cross flow fan increase
airflow to circulate air around a room.
- Auto-Restart after Power Failure
The air conditioner memorises the settings for
mode, airflow, temperature, etc., and automatically returns to them when power
is restored after a power failure.
- Outdoor Unit Quiet Operation
Outdoor unit operating sound pressure levels are
decreased from the rated operation sound using the wireless remote controller.
- Indoor Unit Lamp
The indoor unit is equipped with an operation
lamp, timer lamp and various other indicators. The brightness of these lamps
can be adjusted to High, Low or Off.
- Hot Start Function
After defrosting or when starting heating
operation, air is pre- heated before discharge to prevent uncomfortable cold
drafts.
- Standby Electricity Saving
Even when an air conditioner is not operating, it
requires standby power. However, thanks to this function, the required standby
power can be reduced.
- Daily On-Off Timer
This timer allows users to set the operation
start and stop times so the air conditioner turns on and off at the same time
every day.
- Auto Operation
This function automatically selects cooling or
heating operation mode based on the room temperature at start-up.
- Self-Diagnosis with Digital Display
Malfunction codes are shown on the digital
display panel of the wireless remote controller for fast and easy maintenance.
- Indoor Unit Quiet Operation
Indoor unit operating sound pressure levels are
decreased by 7 to 10 dBA from the Low setting fan speed using the wireless
remote controller.
- Cleaning Filter Operation
After operation stops, this function
automatically brushes dust off the pre-filter and collects it in a box. This
helps to maintain filter performance and energy efficiency.
- Power-Airflow Flap
The Power-Airflow Flap can
flatten out during cooling operation to deliver cool air to the corners of a
room. The flap can direct warm air straight down to the floor during heating
operation.
Hello!
ReplyDeleteMy funny rocketish Urusara's carbon filter is partially ripped, waiting for a replacement as it is just back home from a chemical used cleaning-up from intense internal & external moulding.
Stepped on a ladder to see it's top:I see a thin mesh sheet is covering it but no hard lid like cover to protect the mesh. I wonder if a cover is supposed to be on top of it? If not & it is how it is; shouldn't it collect roomdust on to it, bcs it seems to absorb the air from it's top? Do I gently vacuum it's top sometime later? Or wipe it with a soft-moist cloth to clean?
My unit has been in trouble making a disturbing noise in the nights when heatibg is on after a general maintainance less than a year ago & it has been washed & re-installed 4 times in a year like period. Now the yellow light is still going on blinking as it did through most of the year. Could that happen bcs of it's 6 months guarateed only ripped cata-filter?
I am happy to finally see it without moulding on it's externals & no odour from, as I have allergic asthma. Very worrysome & costly to maintain Urusara7 in my country for the teams often decide all is okay without looking at it closely. Perhaps no one ever needs a +eyeglasses among the +42aged of our kind talking but over-optimistic technicians...builders or the carpenters are the same here. They do never need a ruler. They have eagle's eyes! Then the users suffer!
I strongly suggest DAIKIN employed a pair of young Japanese technicians at every Technical Service Office here to train our over-relaxed eagle-eyes! For the best of our beautiful country & R32-Urusara7.
Before the new 2018 Designed Urusara7 comes by...