Tuesday, May 22, 2018

Five things to be paid attention when acquiring generator


Diesel generator and gasoline generator are generally used in industrial and home for standby power backup so it is very significant to be acquainted on how to use them suitably. Here are five things one should take note when using the generator.

1. Don’t use generator inside a building, including homes, garages, crawlspaces and sheds, as it may speedily reach lethal brought by levels of carbon monoxide.

2. Take the reading of the manual as a helpful guide. Most of people acquire the generator and disregard this key point. It only takes 15 minutes and will provide much guild of using generator.

3. Using the generator in wet condition is hazardous, causing electrical shock or electrocution in the foulest situations. Try to keep rain off the generator, using maybe a canopy to let for open ventilation while keep raindrops from the generator. Make sure that hands are dry before touching the generator.

4. Never plug the generator into a home wall outlet. That could be similar to putting a match into a gas-soaked rag.


5. Keep the fuel in a safe area. Store the gasoline, propane and other flammable liquids in proper safety containers outside of the living areas. Label them when necessary.

Reference:

Things you should know about generator, http://www.bodepower.com/things-you-should-know-about-generator/ 


FOR YOUR GENSET NEEDS, PLEASE FEEL FREE TO CONTACT ALLAN E. ECLEO AT (0917) 883-5922 OR THROUGH allanecleo@gmail.com

Sunday, May 20, 2018

Do’s and Don’ts on Air Conditioning Maintenance


Maintain your HVAC System and reduce overall expenditures through different means:

Install Programmable Thermostat, a one piece of equipment which can save over $180 a year through maintaining a constant temperature throughout home or business. Having a thermostat programmed for time shut offs and zone specific temperatures also provides long term savings.

Clean the Coils on Air Conditioning Unit – a dirty coil can raise air conditioning bill by upwards of 30% by degrading the effect your system has its ability to cool the air affecting the unit to run longer, utilize more power and increase bill. The dirty coil on air conditioning unit can likewise curtail the life of the unit on a whole by a year or more.

Replace the Air Filters of Air Conditioning System – a clean filter lessens the work that an air conditioning unit must perform in order to condition the air. Replacing or cleaning the filter saves up to 5% per month.

Annual Tune-Ups and Frequent HVAC Maintenance – regular air conditioner service, repair and maintenance on HVAC system can keep it at 95% of its original efficiency for up to 15 years. By preserving the unit’s efficiency over time, the cost of a tune-up is quickly recovered through increased cooling and heating capacities and minimized energy bills. The average unit loses 5% efficiency each year without regular upkeep and maintenance, which has a huge impact over time with 25% efficiency lost after the first 5 years.

MYTH: Routine maintenance is not significant "If it's not broke, don't fix it."

FACT: Unrepaired small problems can lead to very costly repairs. Up to 80% of all air conditioning and heat pump compressor failures could be prevented if the problems that lead to the failure are detected on its early stages.


Source: 
http://airdrs.com/air-conditioning-maintenance-dos-and-donts, Air Conditioning Maintenance Do’s and Don’ts







Sunday, April 22, 2018

THE ROLE OF AUTOMATIC GENERATOR AND TRANSFER SWITCH SYSTEM

The totally Automatic Transfer Switch (ATS) checks incoming voltage from the utility line, 24/7.

When utility power is disrupted, the automatic transfer switch instantly senses the problem and signals the genset to start.

If the genset runs at appropriate speed, the Automatic Transfer Switch ATS) securely turn off the utility line and simultaneously opens the generator power line from the generator.

Within seconds, the genset system starts supplying electricity to the critical emergency circuits of home/business. The transfer switch continues to check the conditions of the utility line.

Once the Automatic Transfer Switch (ATS) senses the utility line voltage returned at a stable condition, it re-transfers the electrical load back to the utility line and continues monitoring for successive utility loss. The genset continues to run for an engine cool-down period of several minutes while the entire system stands ready for the following power outage.



Other purposes of a transfer switch. Fire or homeowners insurance may be cancelled when installingl a generator without a transfer switch, as these switches are required by the building code electrical codes in most areas. Provided below are information which explains other data why transfer switches are a requirement. AVOID CONNECTING A GENERATOR THROUGH A DRYER PLUG OR OUTLET IN A BUILDING. IT CAN CAUSE A FIRE OR ELECTROCUTE SOMEONE!



USE A TRANSFER SWITCH  It must be installed by a professional electrician or skilled individual and must be compliant with all pertinent laws and electrical codes.



TRANSFER SWITCH SAFEGUIARDS LINEMAN


The utility line voltage is usually "reduced" before entering the building, by a transformer. The transformer can work in reverse if voltage is sent through it in the opposite direction and "accelerate" the voltage. This accelerated voltage, back-feeding through the utility lines, may electrocute workers that come into contact with the utility lines.


A TRANSFER SWITCH SAFEGUARDS THE HOME


Inappropriate connections can allow electrical current from the genset to short circuit with utility line current if power is resumed. This can trigger a fire in the electrical system.


A TRANSFER SWITCH SHIELDS THE GENERATOR


Inappropriate connections can allow electrical current from the genset to short circuit with utility line current when power is resumed. This could trigger explosion or burning of the genset.


SEVERAL TYPES OF TRANSFER SWITCHES


There are different types of transfer switches that may be used with generators.
These switches are limited to 21,000 watts (21 kW) and are basically manually switched.
Provided below are the details providing specifications and a just a few recommendations for matching a transfer switch to a generator:


TRANSFER SWITCH OPERATION


Small & Portable Generators

The Transfer switch separates selected circuits from the home with "Break" then "Make" switches. Eevery switch has 3-positions; LINE, OFF and GEN (generator). In the LINE spot, utility power feeds the chosen circuits. In the GEN position, generator power feeds the chosen circuits. To switch from LINE to GEN, the switch is led through the OFF position, which lets a positive break to happen, which prevents sparking, arcing or short circuits that might be developed if the positive break was not part of the system.
Individual circuit protectors shield every chosen circuit from overload, allowing a larger generator to be connected to the transfer switch without the transfer switch being overloaded.



These switches can handle different voltages and are generally unlimited in the size available. Basically, they transfer automatically and have a wide range of features like automatic excising, changeable start and stop delay times, changeable cool down times and other features.


Transfer switches are available fused and with breakers. Special switches allow the use of more than one generator at a time, switching between multiple generators and other situations.

Sunday, June 18, 2017

Cummins Diesel Generator Sets Ranging from 600kVA to 3570kVA (50Hz)


You may pick your choice from 631VVA to 3750kVA (505 - 3000KW) diesel generator set range at 50 Hz, based on your requirement:

Model
Standby Rating

kVA
Standby Rating

kW
Prime Rating

kVA
Prime Rating

kW
Continuous Rating

kVA
Continuous Rating

kW
Engine
631
505
575
460
-
-
KTA19
688
500
625
500
-
-
KTA19
706
565
640
512
-
-
VTA28
825
660
750
600
-
-
VTA28
825
660
750
600
-
-
QSK23
900
720
820
656
-
-
QSK23
1041
833
939
751
-
-
QST30
1062
850
1012
810
-
-
KTA38
1110
888
1000
800
-
-
QST30
1132
906
1029
823
-
-
KTA38
1250
1000
1125
900
-
-
KTA38
1400
1120
1275
1020
1025
820
QSK50
1540
1232
1400
1120
1125
900
QSK50
1540
1232
1400
1120
1125
900
QSK50
1700
1360
1540
1232
1250
1000
QSK50
1700
1360
1540
1232
1250
1000
QSK50
1825
1460
1650
1320
1425
1140
QSK50
1400
1120
1250
1000
-
-
KTA50
1675
1340
1400
1120
-
-
KTA50
1675
1340
1500
1200
-
-
KTA50
1760
1408
1600
1280
-
-
QSK60
2063
1650
1875
1500
-
-
QSK60
2000
1600
1825
1460
1400
1120
QSK60
2000
1600
1825
1460
-
-
QSK60
2250
1800
2000
1800
-
-
QSK60
2250
1800
2000
1600
1600
1280
QSK60
2500
2000
2250
1800
-
-
QSK60
2500
2000
2000
1600
-
-
QSK60
2750
2200
2500
2000
2250
1800
QSK78
2750
2200
2500
2000
2000
1600
QSK78
3000
2400
2750
2200
2475
1980
QSK78
3000
2400
2750
2200
2100
1680
QSK78
3500
2800
3125
2500
2600
2080
QSK95
3500
2800
3125
2500
2750
2200
QSK95
3500
4000
4550
3640
3000
2400
QSK95
3750
3000
3350
2680
3000
2400
QSK95

60 Hz diesel generator set range available

Cummins Power Generation designs and produces High Horsepower generator sets, designed to offer emergency backup, critical standby, prime power or peak shaving to applications including:
  • Healthcare
  • Water and waste water treatment plants
  • Manufacturing
  • Government facilities
  • Mining
  • Large commercial buildings
Cummins High Horsepower generator sets are controlled by PowerCommand® digital control technology that integrates with other components of the overall power system and can be effortlessly configured to meet the power generation requirements of clients worldwide.

All of Cumimins high horsepower products are designed and manufactured to give the highest dependability, efficiency and adaptability: 
  • Emergency & standby power
  • Prime Power
  • Peak Power
  • Distributed power
  • Cogeneration
  • Power Management